On July 6, 2010, the NRC issued a Notice of Violation to Laboratory Testing Services, LLC (LTS) for a Severity Level III problem involving three violations. The first violation involved a failure to confine possession and use of byproduct material to the location authorized by the license, as required by 10 CFR 30.34(c). Specifically, the licensee possessed and used portable gauges at a location not authorized by the license. The second violation involved a failure to have an individual named on the license as a Radiation Safety Officer (RSO), as required by the license. Specially, the RSO named in the license left the company in June 2008, and the licensee failed to have an RSO approved by the NRC. The third violation involved a failure to obtain written consent from the NRC before transferring ownership of LTS to HAKS Material Testing Company (HAKS), as required by 10 CFR 30.34(b). Specifically, on January 14, 2010, LTS transferred ownership control of the license to HAKS without the Commission's written consent.